Taiwan KCL VQ SVQ DVQ Hydraulic Single Vane Pump DVQ20-14-F-RAB-02
Taiwan KCL DVQ Hydraulic single vane pump DVQ20-14-F-RAB-02 |
Describe |
1. Lay the suction piping under the fluid level at least 1M. |
2. When connecting the pump to an electric motor, limit the tolerance of alignment between the two shaft centers to 0. 05m/ m TIR or angle1 degree |
3. Before starting, make sure that direction of the electric motor shaft rotates the same direction with the pump shaft as indicated with an the nameplate or on the housing of the pump |
4.In selecting a hydraulic fluid, remember that the minimum permitted temperature in the hydraulic system must be at least 8'C above the pour point. |
5.All the time of first-starting, if the pump does not immediately prime, air should be bled from the pump delivery line. This may be accomplished by loosening a connection in the delivery line close to the pump until oil flows-indicating the pump has primed. An air bleed valve is available for this purpose. |
Hot Tags: taiwan kcl vq svq dvq hydraulic single vane pump dvq20-14-f-rab-02, China, manufacturers, factory, customized, wholesale, quotation, low price, in stock,